Product Big Image
  • Frys.com #1440191
  • Manufacturer: Fluke
  • UPC #095969001120
  • Model #80K-40
  • The 80K-40 is a high voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I. This means the probe can only be used to make measurements on energy limited circuits within equipment. Examples include high voltage within televisions or photo copy machines. DO NOT use this probe to measure high voltages on power distribution systems. The probe provides high accuracy when used with a voltmeter having 10 Megohm input impedance.

     

     

    shipping_info
    In Stock
    Ships Same Business Day
    status_info
    store_pickup


    Detail Description
    Detailed Description
    (Manufacturer # 80K-40 )

    Features
    • A high voltage probe that allows a multimeter to measure up to 40,000V respectively. Intended for low energy applications only
    Specifications:
  • The 80K-40 will achieve rated accuracy when used with a voltmeter (ac or dc) having an input impedance of 10 M? ?1.0%.*
  • Specifications for the probe are as follows: ?Voltage Range: 1 kV to 40 kV dc or peak ac, 28 kV rms ac Input Resistance: 1000 M? Division Ratio: 1000: 1 (1000X attenuator) Accuracy DC: 20 kV to 35 kV: ?1% at 20?C to 30?C; add 1% at 10?C <20?C and >30?C to 45?C. (For total measurement accuracy add accuracy specification of voltmeter being used.) 0 kV to <20 kV and >35 kV to 40 kV: ?2%. Accuracy AC: 60 Hz, ?5%. Safety: Meets IEC 1010-2-031:1993, Type B, 40 kV dc or, peak ac, 28 kV rms ac, Overvoltage Category I (voltages derived from limited energy transformer). * The input impedance of Autoranging Fluke handheld digital multimeters varies as a function of range. The only range that deviates significantly from 10 M? is the 3V (Models 21, 23, 25, 27, 70, 73, 75, 77) or 4V (Models 10, 11, 12, 29, 79, 83, 85, 86, 87, 88) range where the impedance is 11.11 M?. To enhance the measurement accuracy when using this range, apply a correction factor of 0.99, i.e. multiply the displayed reading by .99. ? This probe is intended for low energy applications such as CRT and similar circuits. Above 2000 meters altitude, and up to 5000 meters, derate linearly the working voltage from 40 kV peak to 28 kV peak, and derate linearly the transient overvoltage from 80 kV peak to 57 kV peak. Transient overvoltage refers to micro-second duration impulses caused by lightning or load switching. See International Electrotechnical Commission Publication 664-1980, Clause 3.9 Table II, and Appendix A. Measurement Considerations







  • 157

    In Stock, Same Business Day Shipping
    This product is in stock in our warehouse. You have a choice of Ground Service, 2nd Day Air, or Overnight Delivery for domestic orders.

    DISPLAY ITEM.

    Confirm Availability using In-Store Pickup

    The most recent information shows that this
    product is in-stock at this location, but
    availability is subject to prior sale.
    Ensure availability by reserving this product
    with Free In-Store Pickup.

    OPEN BOX ITEM.

    Sold Out at this store location
    This product is currently sold out at this
    location. Click Change Store to see if it may
    be available for pick-up from another location.

    Show Big Images