Product Big Image
  • Frys.com #5343048
  • Manufacturer: Fluke
  • UPC #095969365390
  • Model #37XR-A
  • True RMS with component and logic test
  • Inductance to 40 H, frequency to 40 MHz,capacitance to 400 uF,logic to 20 MHz
  • Input warning tone when test leads are in wrong jack
  • 10,000 count, 0.1 % accuracy
  • 1000 V/750 V dc/ac True RMS
  • 10 Amps ac/dc, fully safety fused

  •  

     

    shipping_info
    In Stock
    Ships Same Business Day
    status_info
    store_pickup


    Detail Description
    Detailed Description
    (Manufacturer # 37XR-A )

  • DC Voltage Ranges: 1000 mV, 10 V, 100 V, 1000 V
  • DC Voltage Accuracy: all ranges +/-(0.1 % rdg + 5 dgt)
  • DC Voltage Resolution: 100 uV
  • AC Voltage (45 Hz to 2 kHz) True RMS Ranges: 1000 mV, 10 V, 100 V, 750 V
  • AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: 750 V range: 45 to 1 kHz: +/-(2.0 % rdg + 10 dgts)
  • AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 45 to 500 Hz: +/-(1.2 % rdg + 10 dgts)
  • AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 500 to 2 kHz: +/-(2.0 % rdg + 10 dgts)
  • AC Voltage (45 Hz to 2 kHz) True RMS Resolution: 100 uV
  • AC coupled: True RMS specified from 5 % to 100 % of range
  • DC Current Ranges: 100 uA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A
  • DC Current Accuracy: 100 uA range: +/-(0.5 % rdg + 10 dgt)
  • DC Current Accuracy: 1000 uA to 400 mA ranges: +/-(0.5 % rdg + 5 dgts)
  • DC Current Accuracy: 10 A range: +/-(1.5 % rdg + 10 dgt)
  • DC Current Resolution: 0.01 uA
  • AC Current (45 Hz to 1 kHz)True RMS Ranges:100 uA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A
  • AC Current (45 Hz to 1 kHz) True RMS Accuracy: 100 uA to 100 mA ranges: +/-(1.5 % rdg + 10 dgts)
  • AC Current (45 Hz to 1 kHz) True RMS Accuracy: 400 mA range: +/-(2.0 % rdg + 10 dgts)
  • AC Current (45 Hz to 1 kHz) True RMS Accuracy: 10 A range: +/-(2.5 % rdg + 10 dgts)
  • AC Current (45 Hz to 1 kHz) True RMS Resolution: 0.01 uA
  • Resistance Ranges: 1000 Ohm, 10 kOhm, 100 kOhm, 1000 kOhm, 10 MOhm, 40 MOhm
  • Resistance Accuracy: 1000 Ohm to 1000 kOhm ranges: (0.5 % rdg + 8 dgts)
  • Resistance Accuracy: 10 MOhm range: +/-(1.0 % rdg + 10 dgts)
  • Resistance Accuracy: 40 MOhm range: +/-(2.0 % rdg + 10 dgts)
  • Logic Test , Logic Type: TTL, CMOS
  • Warranty: 3 Year
  • Battery Life: 150 hrs typical (alkaline)
  • Size: 7.75" x 3.55" x 2.4" (195 x 92 x 60 mm)
  • Weight: (without holster, including probes)
  • Safety: Cat III 600 V, Cat II 1000 V







  • 103

    In Stock, Same Business Day Shipping
    This product is in stock in our warehouse. You have a choice of Ground Service, 2nd Day Air, or Overnight Delivery for domestic orders.

    DISPLAY ITEM.

    Confirm Availability using In-Store Pickup

    The most recent information shows that this
    product is in-stock at this location, but
    availability is subject to prior sale.
    Ensure availability by reserving this product
    with Free In-Store Pickup.

    OPEN BOX ITEM.

    Sold Out at this store location
    This product is currently sold out at this
    location. Click Change Store to see if it may
    be available for pick-up from another location.

    Show Big Images