Product Big Image
  • Frys.com #4998701
  • Manufacturer: Fluke
  • UPC #095969390514
  • Model #FLUKE-117/R
  • Designed by Electricians. Engineered by Fluke - An Investment in Accuracy With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease. Engineered and Tested with Your Safety on the Job in Mind We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because: The large white LED backlight helps you work in poorly lit areas VoltAlertTM technology gives you fact, go/no go non-contact voltage detection AutoVolt and Low Input Impedance modes provide faster, more accurate readings

     

     

    shipping_info
    In Stock
    Ships Today
    status_info
    We Pay the Sales Tax
    store_pickup


    Detail Description
    Detailed Description
    (Manufacturer # FLUKE-117/R )

    Features
    • VoltAlert™ technology for non-contact voltage detection
    • AutoVolt automatic AC/DC voltage selection
    • Low input impedance: helps prevent false readings due to ghost voltage
    • Large white LED backlight to work in poorly lit areas
    • True RMS for accurate measurements on non-linear loads
    • Measures 10 A (20 A overload for 30-seconds)
    • Resistance, continuity, frequency and capacitance
    • Min/Max/Average with elapsed time to record signal fluctuations
    • Compact ergonomic design for one-handed operation
    • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
    • CAT III 600 V safety rated
    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
    Display Digital:6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating Temperature -10 °C to + 50 °C
    Storage Temperature -40 °C to + 60 °C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life 400 hours typical, without backlight
    DC volts
    Range/Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    Auto volts
    Range/resolution 600.0 V / 0.1 V
    Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts1 true-rms
    Range/resolution 600.0 mV / 0.1 mV
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
    AC volts1 true-rms
    6.000 V / 0.001 V
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity
    Range/resolution 600 Ω / 1 Ω
    Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 µs or longer.
    Ohms
    Range/Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy 0.9% + 1
    Range/Resolution 40.00 MΩ / 0.01 MΩ
    Accuracy 5% + 2
    Diode test
    Range/Resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance
    Range/Resolution 1000 nF / 1 nF
    10.00 µF / 0.01 µF
    100.0 µF / 0.1 µF
    9999 µF / 1 µF
    100 µF to 1000 µF
    Accuracy 1.9% + 2
    Range/resolution > 1000 µF
    Accuracy 5% + 20%
    Lo-Z capacitance
    Range/Resolution 1000 nF / 1 nF
    10.00 µF / 0.01 µF
    100.0 µF / 0.1 µF
    9999 µF / 1 µF
    100 µF to 1000 µF
    Range 1 nF to 500 µF
    Accuracy 10% + 2 typical
    Temperature (Type-K thermocouple)
    Range/resolution -40°C to 400°C / 0.1°C
    Accuracy 1% + 10A?
    DC amps
    Range/resolution 600.0 µA / 0.1 µA
    Accuracy 1.0% + 2
    Hz (V or A input)
    Range/resolution 99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    Accuracy 0.1% + 2








    114

    In Stock, Same Business Day Shipping
    This product is in stock in our warehouse. You have a choice of Ground Service, 2nd Day Air, or Overnight Delivery for domestic orders.

    DISPLAY ITEM.

    Confirm Availability using In-Store Pickup

    The most recent information shows that this
    product is in-stock at this location, but
    availability is subject to prior sale.
    Ensure availability by reserving this product
    with Free In-Store Pickup.

    OPEN BOX ITEM.

    Sold Out at this store location
    This product is currently sold out at this
    location. Click Change Store to see if it may
    be available for pick-up from another location.

    Show Big Images