The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting.

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

    Plus, the Fluke Connect wireless enabled modules measure AC, DC and AC+DC voltage, AC and DC current, plus temperature, all of which display on the Fluke 3000 FC Series Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display and up to three modules at any one time. Modules are available separately or as part of Fluke Connect kits.

    All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher, iPad (in an iPhone frame on iPad) and Galaxy S4, Nexus 5, HTC One running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

  • Detailed Description
    (Manufacturer # FLK-3000 FC )
    Detailed Specifications:
    AC Voltage:
    Range 1 / Resolution:
  • 600.0 mV / 0.1 mV
  • 6.000 V / 0.001 V
  • 60.00 V / 0.01 V
  • 600.0 V / 0.1 V
  • 1000 V / 1 V
  • Accuracy 234
    45 Hz to 500 Hz 1.0 % + 3
    500 Hz to 1 kHz 2.0% + 3
  • 1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
  • 2 Crest factor of ± 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
  • 3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
  • 4 Do not exceed 107 V-Hz.

  • DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function
    mV Range / Resolution 600.0 mV / 0.1 mV Accuracy 0.09 % + 2 V Range / Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V Accuracy 0.09 % + 2 0.15 % + 2
    ))) Range / Resolution 600 Ω / 1 Ω Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
    Ω Range / Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5 % + 2 0.5 % + 1 1.5 % + 3
    Diode test Range / Resolution 2.000 V / 0.001 V Accuracy 1 % + 2
    µF Range / Resolution 1000 nF / 1 nF
    10.00 µF / 0.01 µF
    100.0 µF / 0.1 µF
    9999 µF1 / 1 µF
    Accuracy 1.2 % + 2 10 % typical
    1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.

    AC and DC Current
    Function
    mA AC (45 Hz to 1 kHz) Range 1 / Resolution 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA Accuracy 1.5 % + 3 mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA Accuracy 0.5 % + 3
    1 All AC current ranges are specified from 5 % of range to 100 % of range.
    2 Input burden voltage (typical): 400 mA input 2 mV/mA.
    3 400.0 mA accuracy specified up to 600 mA overload.

    Frequency
    Range / Resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy 1 0.1 % + 1
    1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload protection Input impedance (nominal) Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection 1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    Open circuit test voltage Full scale voltage Typical short circuit current To 6 MΩ 50 MΩ Typical short circuit current 1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA 1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Accuracy DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.

    General Specifications
    Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate 4/sec Volts, amps, ohms 6000 counts Frequency 10,000 counts Capacitance 1,000 counts Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20m
    Obstructed, sheetrock wall Up to 6.5m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
    Temperature Operating -10 °C to 50 °C
    Storage -40 °C to 60 °C
    Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Relative humidity 0 % to 90 % (0 ?C to 35 ?C)
    0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
    Weight 340 g (12 oz)

    Note: Not compatible with Fluke CNX test tools All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher, iPad (in an iPhone frame on iPad) and Galaxy S4, Nexus 5, HTC One running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

  • For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %.
    Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).
  • Requirements