FRYS.com | Fluke
click image to see larger view
Scope Meter Digital Multimeter
Scope Meter Digital Multimeter
Scope Meter Digital Multimeter
Scope Meter Digital Multimeter

Fluke 123B Industrial ScopeMeter Handheld Oscilloscope

Frys#: 8955393 Model: FLUKE-123B/NA
Price Match Request
$1,499.99
Clearance
Special Price
Coming Soon
open box starting at $17,990.99

*Please enter your ZIP Code to view PSC availabilty

Overall Customer Rating

Simplified testing, more insight and faster electro-mechanical troubleshooting

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

Equipment Pictured Sold Separately.

Detailed Description
(Manufacturer # FLUKE-123B/NA )
Features
  • Features two 5,000-count True-RMS digital multimeters
  • Offers recorder Event Detect to capture elusive intermittent signals on repetitive waveforms up to 4 kHz
  • Comes with shielded test leads for oscilloscope, resistance and continuity measurements
  • Features resistance, continuity, diode, and capacitance meter measurements
  • Performs power measurements (W, VA, VAR, PF, DPF, Hz)
  • Measures voltage, current and power harmonics
  • Check Industrial networks with BusHealth physical layer tests against defined reference levels (125B only)
  • Allows you to save and recall data and instrument setups
  • Includes FlukeView® ScopeMeter® software for Windows®
  • Features a rugged design to withstand 3g vibration, 30g shock, and rated IP51 according to EN/IEC60529
  • Runs on a Li-Ion rechargeable battery providing seven-hours operation (with four-hour charge time)
  • Features highest safety rating in the industry: safety rated for CAT IV 600 V
Specifications
Oscilloscope Mode Vertical
Frequency response - dc coupled Without probes and test leads (with BB120) : 123B: dc to 20 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads : DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
With VP41 10:1 Probe/123B: dc to 20MHz (-3 dB)
Frequency response - ac coupled (lf roll off) Without probes and test leads /< 10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads/ < 10 Hz (-3 dB)
With VP41 10:1 Probe / < 10 Hz (-3 dB)
Rise time, excluding probes,test leads 123B < 17.5 ns
Input impedance Without probes and test leads / 1 MΩ/20 pF
With BB120 / 1 MΩ//24 pF
With STL120-IV 1:1 shielded test leads / 1 MΩ//230 pF
With VP41 10:1 Probe / 5 MΩ//15.5 pF
Sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10 kHz
Display modes A, -A, B, -B
Max. input voltage A and B Direct, with test leads, or with VP41 Probe /600 Vrms Cat IV, 750 Vrms maximum voltage.
With BB120 /600 Vrms
Max. floating voltage, from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400Hz
Oscilloscope Mode Horizontal
Scope modes Normal, Single, Roll
Ranges (normal) Equivalent sampling / 123B: 20 ns to 500 ns/div
Real time sampling / 1 μs to 5 s/div
Single (real time)/ 1 μs to 5 s/div
Roll (real time) / 1s to 60 s/div
Sampling rate (for both channels simultaneously) Equivalent sampling (repetitive signals) / Up to 4 GS/s
Real time sampling 1 μs to 60 s/div / 40 MS/s
Trigger
Screen update Free run, on trigger
Source A, B
Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV
@ 40 MHz 123B: 4 divisions
@ 60 MHz 123B: N/A
Slope Positive, negative
Advanced scope functions
Display modes Normal : Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth : Suppresses noise from a waveform
Glitch off : Does not capture glitches between samples
Envelope : Records and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™) Continuous fully automatic adjustments of amplitude, time base, trigger levels,
trigger gap, and hold-off. Manual override by user adjustment of amplitude,
time base,or trigger level.
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts)
from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage
measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen.
Input A and input B DC voltage (VDC)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy ±(0.5% +5 counts)
Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V ac+dc) /±(1% +10 counts)
1 Hz to 60 Hz (V ac) /±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled) 60 Hz to 20 kHz/±(2.5% +15 counts)
DC rejection (only VAC) >50 dB
Common mode rejection (CMRR) >100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts, reading is independent of any signal crest factor.
Peak
Modes Max peak, Min peak, or pk-to-pk
Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy Accuracy Max peak or Min peak/5% of full scale
Accuracy Peak-to-Peak /10% of full scale
Full scale reading 500 counts
Frequency (Hz)
Ranges 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz,
100 kHz,1 MHz, 10 MHz, and 50 MHz
Frequency range 15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz ±(0.5% +2 counts)
Full scale reading 10,000 counts
RPM
Max reading 50.00 kRPM
Accuracy ±(0.5% +2 counts)
Duty cycle (PULSE)
Range 2% to 98%
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading 1000 counts
Amperes (AMP)
With current clamp Ranges : Same as V dc, V ac, V ac+dc, or PEAK
Scale factors : 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy : Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with optional temperature probe
Range 200 °C/div (200 °F/div)
Scale factor 1 mV/°C and 1 mV/°F
Accuracy As V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV 1 V
0 dBm (600 Ω /50 Ω) 1 mW referenced to 600 Ω or 50 Ω
dB on V dc, V ac, or Vac+dc
Full scale reading 1000 counts
Crest factor (CREST)
Range 1 to 10
Full scale reading 90 Counts
Phase
Modes A to B, B to A
Range 0 to 359 degrees
Resolution 1 degree
Input A to common Ohm (Ω)
Ranges 123B : 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current 0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage < 4 V
Continuity (Cont)
Beep <(30 Ω ±5 Ω) in 50 Ω range
Measurement current 0.5 mA
Detection of shorts of ≥1 ms
Diode
Measurement voltage @0.5 mA / >2.8 V
@open circuit / < 4 V
Measurement current 0.5 mA
Polarity + on input A, - on COM
Capacitance (CAP)
Ranges 50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading 5000 counts
Measurement current 500 nA to 0.5 mA, increases with increasing ranges
Advanced meter functions
Zero Set Set actual value to reference
AutoHold (on A) Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point Activated by using attenuation keys
Miscellaneous
Display Type : 5.7-inch color active matrix TFT
Resolution : 640 x 480 pixels
Waveform Display Vertical : 10 div of 40 pixels
Horizontal : 12 div of 40 pixels
Power External : Via Power Adapter BC430
Input voltage : 10 V DC to 21 V DC
Power consumption : 5 W typical
Input connector : 5 mm jack
Internal : Via Battery Pack BP290
Battery power : Rechargeable Li-Ion 10.8 V
Operating time : 7 hours with 50% backlight brightness
Charging time : 4 hours with test tool off, 7 hours with test tool on
Allowable ambient temp : 0 to 40 °C (32 to 104 °F) during charging
Memory Internal memory can store 20 data sets (screen waveform and setup)
Micro SD card slot with optional SD card (max size of 32 GB)
Mechanical Size : 259 x 132 x 55 mm (10.2 x 5.2 x 2.15 in)
Weight : 1.4 kg (3.2 lb) including battery pack
Interface Optically isolated : Transfer screen copies (bitmaps), settings and data
USB to PC/laptop : OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi adapter : Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
Environmental
Environmental MIL-PRF-28800F, Class 2
Temperature Battery Operation : 0 to 40 °C (32 to 104 °F)
Power Adapter Operation : 0 to 50 °C (32 to 122 °F)
Storage : -20 to 60 °C (-4 to 140 °F)
Humidity (Operating) @ 0 to 10 °C (32 to 50 °F) / Non-condensing
@ 10 to 30 °C (50 to 86 °F) / 95%
@ 30 to 40 °C (86 to 104 °F) / 75%
@ 40 to 50 °C (104 to 122 °F)/ 45%
Altitude Operating at 3 km (10,000 feet) / CAT III 600 V
Operating at 2 km (6,600 feet) /CAT IV 600 V
Storage /12 km (40,000 feet)
EMC electromagnetic compatibility International : IEC 61326-1: Industrial, CISPR 11: Group 1, Class A
Korea (KCC) : Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC) : 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter Frequency range :2412 MHz to 2462 MHz
Output power : < 100 mW
Enclosure protection IP51, ref: EN/IEC60529
Safety General : IEC 61010-1: Pollution Degree 2
Measurement : IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and B Direct on input or with leads /600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120 / 600 Vrms for derating
Max. floating voltage from any terminal to ground /600 Vrms Cat IV, 750 Vrms up to 400 Hz
Specifications
Brand Fluke
Condition New
UPC 095969814737
10000     